II905 Acoustic Imager And SB140 Beacon
SB140 Beacon showing aircraft application

FLK-II915 Imager Features and Specifications

    Key Specs

  • Frequency Range: 2 to 100 kHz
  • Operation Distance: Up to 120 meters (393 feet)
    Depending on ambient conditions
  • Field-of-View (FOV): 63± 5 Degrees
  • Nominal Frame Rate: 25 FPS (frames per second)
  • Resolution: 5.0 MP (megapixels)
  • Zoom: 3 x digital zoom
  • Touchscreen: Capacitive
  • Display: 7-inch LCD with backlight, sunlight readable
  • Memory/Storage Capacity: 32 GB
  • Image Format: Blended visual and SoundMap .JPG or .PNG
  • Video Format: Blended visual and SoundMap .MP4
  • Save Video: Up to 5 minutes
  • Interface: USB-C for data transfer
  • Connectivity: Wi-Fi enabled

  • Acoustic Measurements Range:

  • 12.1 to 114.6 dB SPL (± 1 dB SPL 2 kHz)
  • 4.4 to 101.2 dB SPL (± 2 dB SPL 19 kHz)
  • 12.8 to 119.2 dB SPL (± 1 dB SPL 35 kHz)
  • 19.8 to 116.1 dB SPL (± 3 dB SPL 52 kHz)
  • 41.4 to 129.0 dB SPL (± 1 dB SPL 80 kHz)
  • 54.4 to 135.5 dB SPL (± 1 dB SPL 100 kHz)

  • More Highlights:

  • Improved leak rate quantification
  • LeakQ - Leak size scale, leak rate, and leak cost estimation
  • PDQ Mode - Translates the sound of partial discharge into visuals
  • MecQ - Enables efficient scanning of large areas
  • Automatic capture upload to Fluke Connect Desktop via Cloud
  • New improved ii-Series reporting platform
  • On-device real time data
  • Customizable profiles for different inspection types
  • Stay powered all day with six hours of operating time

Technician holding Fluke acoustic imager

Reduce Downtime And Locate Leaks Visually

The all-in-one tool you have been looking for to visualize leaks, partial discharge, and mechanical issues. The ii915 Acoustic Imager empowers technicians with the ability to visualize sound while inspecting hoses, fittings, and connections for leaks. It comes equipped with an acoustic array composed of minute, highly sensitive microphones that produce a range of decibel levels for each frequency. Utilizing this data, an algorithm generates a sonic image, termed as SoundMap, which is overlaid on a visual image. The SoundMap adjusts automatically based on the chosen frequency level, effectively eliminating background noise. This makes the detection of compressed gas leaks remarkably straightforward.


First-Line Inspection to Locate Potential Mechanical Issues Early

The Fluke ii915 equipped with MecQ is revolutionizing the industry by facilitating effective scanning of expansive areas, identifying and recording potential problems for focused maintenance. Its non-contact scanning and sophisticated noise reduction capabilities make the Fluke ii915 Acoustic Imager with MecQ Mode a safe choice that provides sharp images even in environments with high noise levels. By identifying potential issues at an early stage, it gives users peace of mind and allows them to take preventative actions to avoid expensive complications, thus outperforming conventional methods.


Partial Discharge: The Invisible Threat…Now You Can See

Partial discharge, a critical problem that can result in arc flash fires, power outages, explosions, and risk to human life, is now a detectable hazard. Whether your task involves examining insulators, transformers, switch gears, or high-voltage power lines, the Fluke ii915 Acoustic Imager with PDQ Mode is your proactive instrument. This device, crafted for high-voltage electricians, electrical testing engineers, and grid maintenance crews, converts the sound of partial discharge into visual data that identifies the exact location. With a broad frequency range of 2-100 kHz, the ii915 facilitates the early identification of potential issues, enabling you to schedule maintenance and avert disastrous incidents.

ii Series Breakout - Interface Features

Feature

ii500

ii905

ii915

LeakQ

Scale (1-10)

Leak size scale, leak rate,
and leak cost estimation

Leak size scale, leak rate,
and leak cost estimation

PDQ Mode



•

MecQ



•

Wi-Fi


•

•

Frequency

2 to 52 kHz

2 to 65 kHz

2 to 100 kHz

Detection Range

Up to 50 meters (164 feet)*

Up to 70 meters (230 feet)*

Up to 120 meters (393 feet)*

Visual Camera Resolution

0.3 MP

5.0 MP

5.0 MP

Battery Life

6 hours

6 hours

6 hours

Memory

20 GB

32 GB

32 GB

Tripod Connector


•

•


Brand: Fluke
Resolution: 5.0 megapixel
Display Type: 7" LCD
Series: ii Series
Alternate Product Number: 6053146
Connectivity: WiFi
Display: 1280 x 800
Frequency Range: 2 to 100 kHz
Includes: Sound Beacon unit, 9 V Battery, Soft Case, Accessory 1 inch probe, Instruction Sheet, and Warranty Card, 1X ii915 Main Body; 1X Hand Strap; 2X Sensor Array Cover; 1X Sensor Array; 1X Neckstrap; 1X USB-C Cable; 1X BP291; 1X Battery Charger ; 1X EDBC290; 1X
Interface: USB-C, WiFi
Operating Temperature Range: -10 to 45C
Type: Acoustic Leak Detector