JensenTools
Fluke
Fluke

Fluke 5606-50-G Probe, Immersion PRT, 50mm, Gold Pin Termination, -200 To 160C, 5606 Series

Our Part #36397.1

Condition:New

Mfr Part #5606-50-G

Fluke 5606-50-G
Fluke
Fluke

Fluke 5606-50-G Probe, Immersion PRT, 50mm, Gold Pin Termination, -200 To 160C, 5606 Series

Our Part #36397.1

Condition:New

Mfr Part #5606-50-G

$733.00EACH

Fluke 5606-50-G Full Immersion PRT

Features and Specifications

  • Termination: G (gold pins)
  • Sheath length: 2 inches (50 mm) in length
  • Sheath diameter: 1/8 inch (3.1 mm)
  • Transition junction temperature range: -200 C to 160 C
  • 100 ohm precision sensing element
  • Calibration accuracy: +/- 0.05 C
  • Minimum insulation resistance: 20 Megohm at 23 C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • Lead-wire cable type: single-conductor enameled copper wire
  • Lead-wire length: 2.4 meters (8 ft)

Compatible With

  • 1523 and 1524 Handheld Thermometer Readout
  • Calibration 1502A and 1504 Thermometer Readout
  • 1529 Chub-E4 Standards Thermometer
  • 1586A Super-DAQ Precision Temperature Scanner

5606-50-G Overview

The 5606-50-G PRT (platinum resistance thermometer) is only two inches (50 mm) long with a sheath diameter of 1/8 inch (3.1 mm) and features a termination of gold pins. It can be completely submerged in its entire temperature range, eliminating the need to determine the minimum depth of immersion. The entire probe, including the transition junction and lead wires, can be immersed in non-corrosive liquids or dry mediums with temperatures ranging from –200 to 160 Celcius.

The 5606-50-G Full Immersion PRT is designed to function in harsh conditions where both the transition junction and the lead wires need to endure temperatures spanning the probe's entire operational range. In this context, "immersion" simply denotes exposure to non-ambient temperatures and does not specifically refer to the medium in which the PRT and its components are placed.

The 5606 Series

The 5606 Series of PRTs have been tested and proven to work effectively in common heat transfer fluids such as silicone oil, mineral oil, ethanol, and even liquid nitrogen without any damage to the transition junction seal or lead wire insulation.

Applications where "full immersion" of probe, transition junction, and lead wire is required can include calibration or validation of sensors used in laboratory or bio freezers, walk-in refrigerators, autoclaves, ovens, stability test chambers, furnaces or incubators. Other applications might include IQ/OQ/PQ qualification procedures, temperature mapping, or data logging in temperature controlled spaces or environmental chambers.

Specifications for the 5606-50-X models are as follows, where X = termination:

  • A (INFO-CON for 914X)
  • B (bare wire)
  • D (5-pin DIN for Tweener Thermometers)
  • G (gold pins)
  • I (INFO-CON for 1521 or 1522)
  • J (banana plugs)
  • L (mini spade lugs)
  • M (mini banana plugs)
  • P (INFO-CON for 1523 or 1524)
  • S (spade lugs)

What's in the Box

  • 5606-50-G Immersion PRT w/ gold pins

*Note: This model does not include calibration. NVLAP-accredited calibration is optional.


Brand: Fluke
Series: 5606 Series
$733.00EACH